FDS FireSmart

FDS FireSmart was previously an addressable, intelligent control system with the ability to integrate several fire safety systems into a single control.

Now, it is much more, providing lifesaving smoke ventilation systems that assist occupant's means of escape and provide clear access for firefighting services.

What's more, these systems are comprised of several high-quality fire safety components to form both a complete and compliant smoke ventilation system.

Mechanical Smoke Ventilation

Mechanical Smoke Ventilation Systems

The FDS FireSmart Mechanical smoke ventilation system is powered by fans to remove smoke from a building to provide a means of escape for occupants and access for fire-fighting services if a fire should occur.

Learn More
Natural Smoke Ventilation

Natural Smoke Ventilation Systems

Natural Smoke Ventilation Systems from FDS FireSmart make us of ‘passive’ forces of wind and thermal buoyancy to provide a safe escape route for a building’s occupants.

Learn More
Car Park Ventilation

Car Park Smoke Ventilation

Car Park Ventilation from FDS FireSmart is called into action in the event of a fire, but also works day-to-day, maintaining a suitable level of air quality by exhausting pollutants, gases and fumes produced by vehicles.

Learn More

FireSmart Components

The systems included as part of the FDS FireSmart package have been made up of high-quality components, dedicated to providing the safest and most compliant smoke ventilation solutions. To secure a consistent supply of high-quality components, FDS FireSmart partners with several strong and reputable suppliers.

Fieger Louvre 1.0

Fieger Louvre 1.0

FDS FireSmart Fieger louvre vents are especially suitable for smoke extraction of buildings, having been tested and certified in accordance with EN 12101-2. Known for their security, stability and practicality, as well as adding individuality to your building. Anything from ...

Fieger Louvre 1.5

Fieger Louvre 1.5

FDS FireSmart Fieger louvre vents are especially suitable for smoke extraction of buildings, having been tested and certified in accordance with EN 12101-2. Known for their security, stability and practicality, as well as adding individuality to your building. Anything from ...

Vent 1.5m2

Vent 1.5m2

The FDS FireSmart 1.5m2 Vent is an attractive, economical low profile louvred ventilator which has been specifically designed for both smoke and heat exhaust and natural ventilation applications. ...

Vent 1m2

Vent 1m2

The FDS FireSmart 1m2 Access Vent was designed and developed to allow dual-use at the head of the stair or within a lobby. ...

Vent 1.5m2 Access

Vent 1.5m2 Access

The FDS FireSmart 1.5m2 Access Vent was designed and developed to allow dual-use at the head of the stair or within a lobby. ...

Vent 1m2 Access

Vent 1m2 Access

The FDS FireSmart 1m2 Vent is an attractive, economical low profile louvred ventilator which has been specifically designed for both smoke and heat exhaust and natural ventilation applications. ...

Power Supply 3 & 5AMP

Power Supply 3 & 5AMP

The FDS FireSmart S406/S407 power supply/battery charger has been developed using switched-mode technology to produce an efficient and lightweight power unit for a host of fire alarm applications. ...

Power Supply 10AMP

Power Supply 10AMP

The FDS FireSmart S408 is an EN54-4 Approved, universal input switching power supply capable of delivering a full 240W of continuous power for fire alarm systems. ...

Stirling Casement Ventilator

Stirling Casement Ventilator

The FDS FireSmart Stirling smoke and heat exhaust ventilator (SHEV) is constructed from extruded AW 6063-T6 aluminium alloys manufactured to EN775 specification. Incorporated within the extrusion profiles is provision for dual weather sealing, control mechanism attachment, hinge location and standard ...

Changeover Panel

Changeover Panel

The FDS FireSmart Changeover Panel is a device that automatically transfers a power supply from its primary source to a backup source when it senses a failure or outage in the primary source. ...

FireSmart

FireSmart

‘FireSmart’ is an addressable intelligent control system with the ability to integrate fire safety systems into a single control. It provides the ultimate notification and operation of essential life safety systems in both normal and fire conditions. ...

Motor Control Panel

Motor Control Panel

Maecenas faucibus mollis interdum. Nullam id dolor id nibh ultricies vehicula ut id elit. Aenean lacinia bibendum nulla sed consectetur. Nullam id dolor id nibh ultricies vehicula ut id elit. Sed posuere consectetur est at lobortis. Donec id elit non ...

Environmental Ceiling Damper

Environmental Ceiling Damper

The FDS FireSmart Environmental Ceiling Damper (ECD) has been designed for use within ceiling voids to allow the movement of air typically between the occupied area and extraction riser. ...

LDN Damper

LDN Damper

The FDS FireSmart Lobby Damper Natural (LDN) has been developed for use in natural smoke control systems serving multi-storey buildings for both domestic and commercial smoke extraction shafts. ...

LD Damper

LD Damper

The FDS FireSmart LD series Lobby Damper has been primarily developed for use in smoke control systems serving multi-storey buildings for both domestic and commercial smoke extraction shafts. ...

Induction Fan JVC F3B-100N

Induction Fan JVC F3B-100N

The FDS FireSmart induction fan has been specifically designed to provide high velocity, laminar airflow in a reduced height profile to help overcome problems caused by obstructive structural beams and low overall ceiling heights found in car parks ...

Induction Fan JVC F3B-50N

Induction Fan JVC F3B-50N

The FDS FireSmart induction fan has been specifically designed to provide high velocity, laminar airflow in a reduced height profile to help overcome problems caused by obstructive structural beams and low overall ceiling heights found in car parks. ...

Impulse Fan

Impulse Fan

The FDS FireSmart Axial Impulse fan has been specifically designed to provide high-velocity airflow to help overcome problems caused by obstructive structural beams and low overall ceiling heights found in car parks. ...

Car Park Main Extract Fan

Car Park Main Extract Fan

The FDS FireSmart main smoke extract fan is rated to 300°C for 2 hours. Both duty and standby fans are provided and will change over automatically on failure of a fan. This is achieved by CTT monitoring of the supply ...

710 Smoke Fan

710 Smoke Fan

The FDS FireSmart Smoke Fan has been specifically developed for emergency smoke extract. ...

630 Smoke Fan

630 Smoke Fan

The FDS FireSmart Smoke Fan has been specifically developed for emergency smoke extract. ...

560 Smoke Fan

560 Smoke Fan

The FDS FireSmart Smoke Fan has been specifically developed for emergency smoke extract. ...

430 Smoke Fan

430 Smoke Fan

The FDS FireSmart Smoke Fan has been specifically developed for emergency smoke extract. ...

Wall Opensky

Wall Opensky

The FDS FireSmart Wall Opensky is an attractive, economical low profile louvred ventilator which has been specifically designed for both smoke and heat exhaust and natural ventilation applications. ...

Roof Opensky

Roof Opensky

The FDS FireSmart Roof Opensky is an attractive, economical low profile louvred ventilator which has been specifically designed for both smoke and heat exhaust and natural ventilation applications. ...

Penthouse Louvre

Penthouse Louvre

The FDS FireSmart ‘Penthouse Louvre’ was designed and developed to allow permanent venting of stairs and air shafts without any moving parts. The Penthouse Louvre can also incorporate an access unit allowing access onto the roof of a building. ...

Louvred Access Smoke Vent

Louvred Access Smoke Vent

The FDS FireSmart ‘Louvred Roof Vent’ was designed and developed to allow dual-use at the head of the stair or within a lobby. ...

Krystalite Glazed Louvre

Krystalite Glazed Louvre

The FDS FireSmart Krystalite glass louvre is a product which in itself is a system – easily extended and adapted to integrate with 21st century structures. Not only is it suitable for installation into all types of vertical glazing and ...

Glazed Ultrasky

Glazed Ultrasky

The FDS FireSmart Ultrasky is a high quality glazed natural ventilator designed for both smoke and natural ventilation requirements. It’s extremely low air permeability characteristics, low profile and aesthetic features offer the ideal solution for modern buildings of a high ...


Mechanical Smoke Ventilation Systems

Mechanical Smoke Ventilation from FDS FireSmart aid the safe escape of occupants' and allows adequate access for firefighters. Our Mechanical Smoke Ventilation Systems (MSVS) are an alternative method to Natural Smoke Venting.

This type of smoke extraction system comprises of a mechanical extract shaft that serves the common corridor and/ or lobby. When smoke it detected within a protected lobby, only the fire damper to the smoke shaft on the fire floor will open (all other dampers will remain locked shut). In turn, the vent at the head of the staircase will open allowing the smoke to be removed and make up air for the smoke extraction system.

The fan at the top of the mechanical smoke shaft extracts the smoke and prevents migration of smoke into the adjacent compartments. Thus, aiding the occupants' means of escape and providing suitable access for firefighting services.

Natural Smoke Ventilation Systems

Natural Smoke Ventilation Systems from FDS FireSmart remain sympathetic to the architect's aesthetic vision, while offering maximum floor space efficiency and cost savings. It is a total solution that provides a reliable and cost-effective method of meeting the requirements of Approved Document B.

In the event of a fire, natural venting systems open air ways, using natural air flow dynamics to remove smoke, which is arguably the biggest threat to life. This can be attained by opening windows or vents, an automatic opening vent (AOV) or, where there is no external wall, a vertical smoke shaft.

This creates a natural air flow to purge smoke from the building and exhaust it into the atmosphere, offering a safe means of escape for occupants, with greater visibility and access for fire fighters.



Car Park Smoke Ventilation

Using CO monitoring and a stepped control algorithm, FDS FireSmart ensures there is sufficient air extraction to remove day-to-day pollutants properly, while maintaining maximum energy efficiency

Smoke is a real threat to life in an enclosed space such as an underground car park and also causes significant issues for fire fighters dealing with the fire.

FDS FireSmarts' smoke extraction and ventilation systems are designed to rapidly remove smoke during and after a fire.

Why choose a MSVS?

Substantial space saving benefits creating more saleable space

The standard states that mechanical smoke shaft systems can be used, provided they offer equivalent performance to their 1.5m² natural counterparts. Due to the greater efficiency of mechanical systems, this can enable the use of shafts as small as 0.25m² in some circumstances, although typically these are 0.5m² or 0.6m², providing substantial space saving benefits over natural systems, creating more saleable space within a property.

Suitable where common corridor travel distances extend over 7.5m

Protecting the building’s staircase, these systems can also be implemented in buildings that contain travel distances in the common corridor that extend over the code recommended 7.5m. This is because they offer greater performance for means of escape, assisting in clearing smoke from the building’s common corridors, mitigating this non-compliance.

Why choose a NSVS?

Aesthetics, Space, Maintenance and Cost Efficiency

If the property’s common corridor has an external wall, natural smoke ventilation systems are a particularly cost-effective method of achieving compliance as existing windows can be used for this purpose.

Whilst remaining sympathetic to the architect’s aesthetic vision, as well as offering maximum floor space efficiency and cost savings, natural systems also offer the advantage of easy maintenance due to the small amount of mechanical parts included, often simply consisting of fire doors and an actuator.

This lack of required maintenance makes natural systems ideal for use in multi-occupancy properties where maintenance budgets are limited, or where systems may be vandalised.

Request a Call Back

Download our Smoke Ventilation System PDF Guide to help you understand the elements of a system and how they interact with each other.

Copyright © 2014 - 2020 Fire Design Solutions

Terms & Conditions | Sitemap | Website Design

Registered Office: 152-154 London Road, Greenhithe, Dartford, Kent, DA9 9JW.
Registered in England: 04460351